MODE/PROG,MAN
SNSET/DEPTH, 1.0
F(CR_44) = FEAT/CIRCLE,INNER,CART, -0.000, -67.000, 3.500, 0.000, 0.000,1.000, 12.500
MEAS/CIRCLE, F(CR_44), 4
PTMEAS/CART, -2.294, -61.186, 2.500, 0.367, -0.930, 0.000
PTMEAS/CART, -5.814, -69.294, 2.500, 0.930, 0.367, 0.000
PTMEAS/CART, 2.294, -72.814, 2.500, -0.367, 0.930, 0.000
PTMEAS/CART, 5.814, -64.706, 2.500, -0.930, -0.367, 0.000
ENDMES

Above codes are pure DMIS, but if you think it will run exactly same in all DMIS based software then you're totally wrong. If you run it in OpenDmis, the circle will be measured at z=2.5 height no matter what the depth setting value is; but in Camio/Modus, the circle will be measured at z=1.5 height. To learn more about DMIS coding, get your on-line video training membership: http://www.rxmetrology.com/membership.html